0314042179
18-250M model is the first of our larger models with the internal capacity to handle sizeable batch loads of medical waste. As standard you get controlled air incineration, automated burn cycles, remote monitoring and alarms. This unit offers optimal combustion conditions for the most challenging waste streams. Its large opening gives you the best design for easy access and continuous loading. This unit benefits from a large secondary chamber with afterburner for the re-burn of harmful emissions at over 850°C with a 2 second retention time. Offers you real economies around medical waste.
❍Medical waste services ❍Mortuary & Autopsy waste
❍Hospitals & large clinics ❍Infectious waste
❍Remote camps ❍Large Nursing homes
Operational specs |
Physical specs |
||
Combustion Chamber volume (m³) |
2.4m³ |
Door size(mm) |
2530 x 1060 |
Burn rate |
Up to 150kg p/h |
External length(mm) |
3590 |
Average fuel . consumption |
25-30ltrs p/h |
External width (mm) |
1390 |
Operational temperature |
850°C + |
External Height (mm) |
4640 |
Gas Retention in Secondary Chamber |
2 secs |
Shipping Weight |
8000kg |
Temperature monitoring |
Yes |
|
|
Average ash residue (%) |
3% |
Optimal Batch size |
35-60kg |
Thermostatic device |
Yes |
Optimal Reload time |
12 minutes |
Remote monitoring |
Optional |
Loading method |
Top or Autoload |